Profibus DP

Profibus DP

LenS19

PROFIBUS-DP is often used for large machines. For production processes requiring fast data transfer, these modules can provide data transmission rates of up to 12 Mbit/s.

Type Communication module PROFIBUS DP

 

 Order designation EMF2133IB
Topology Without repeaters: line;
with repeaters: line or tree
 
Max. no. of devices  31 slaves in one bus segment,
with repeaters: 125 slaves (including repeaters)
Max. size  In one bus segment depends on the transmission rate => max. 1200 m
Transmission medium  Shielded twisted pair
Transmission rate 9,6 - 12000 kBit/s
Process data size 1-12 process data words (the useful process data size depends on the drive controller used)
Suitable for use with 8200; 8200vector; 9300 (all versions); DrivePLC, ECS-servo system
Special features DIP switch for setting the address and setting up compatibility with the 2131IB module; electrically isolated from PROFIBUS-DP
Type Function module PROFIBUS

 

Function module PROFIBUS
 Order designation E82ZAFPC E82ZAFPC V001
Topology Without repeaters: line;
with repeaters: line or tree
 
Without repeaters: line;
with repeaters: line or tree
 
Max. no. of devices  31 slaves in one bus segment,
with repeaters: 125 slaves (including repeaters)
 31 slaves in one bus segment,
with repeaters: 125 slaves (including repeaters)
Max. size  In one bus segment Depends on the transmission rate => max. 1200 m In one bus segment Depends on the transmission rate => max. 1200 m 
Transmission medium  Shielded twisted pair Shielded twisted pair 
Transmission rate 9,6 - 12000 kBit/s 9,6 - 12000 kBit/s
Process data size  1 word - 10 words 1 word - 10 words
Suitable for use with 8200 vector 8200 vector, 8200 motec, starttec
Special features Terminal for activating the controller inhibit and for the external power supply to the module Coated version of the E82ZAFPC module
Type Function module PROFIBUS PT

 

 Order designation E82ZAFPC V010
Topology Without repeaters: line;
with repeaters: line or tree
 
Max. no. of devices  31 slaves in one bus segment,
with repeaters: 125 slaves (including repeaters)
Max. size  In one bus segment Depends on the transmission rate => max. 1200 m
Transmission medium  Shielded twisted pair
Transmission rate 9,6 - 12000 kBit/s
Process data size  1 word - 10 words
Suitable for use with 8200 vector
Special features As the E82ZAFPC but with plug-in terminals

 

Type Function module
PROFIBUS I/O

 

Order designation E82ZAFPC V201
Topology Without repeater: line;
with repeater: line or tree
 
Max. no. of devices   31 slaves in one bus segment,
with repeaters: 125 slaves (including repeaters)
Max. size   In one bus segment, depends on the baud rate => max. 1200m
Transmission medium   Shielded twisted pair
Transmission rate 9.6 - 12000 kBit/s
Process data size   1 word - 10 words
Suitable for use with 8200 vector, 8200 motec, starttec
Special features Coated; terminal for activation of the controller inhibit and for the external supply to the module, 2 freely configurable digital inputs; DIP switches for setting the address, PROFIDrive parameter channel (DP-V1)*


*in preparation