Phân phối Lenze Automation Modular I/O-System

Modular I/O-System

Modular I/O-System

LenS5

 

The ideal solution for every customer

The increasing level of automation in machines and systems and the consequent rise in the number of I/O devices have in turn increased the amount of wiring required. Lenze�s distributed I/O systems with IP 20 protection bring order to this chaos. They are flexible systems, customised for individual applications, which provide functions for implementing all types of applications.

Lenze�s offer comprises two product concepts:

  • A compact system for basic digital applications
  • A modular system for more complex automation tasks

Benefits for customers

  • Maximum reliability
    Lenze is your single source for automation needs. A tailor-made system with common software for all components along with proven preconfigured software solutions reduces the time spent in planning phases - the value of such savings cannot be over-estimated.
  • Optimising the use of space
    The compact dimensions will enable you to save space in your control cabinet. The 1 or 3-wire design can also be extended as required and is supplied with a fixed number of channels as standard. This means that you are free to choose which product to use to solve your application.
  • Reducing training needs
    Because the modules in both concepts are operated in exactly the same way, they can be combined easily. Both concepts share the same bus, field wiring and power supply connection technology for commissioning purposes - this saves time.

 

  • Ease of replacement
    Replacing the electronics module takes just three steps. The terminal strip ensures that the field wiring remains in place. Simply remove the terminal strip, replace the electronics module, and replace the terminal strip - done.

     


The modular system has been designed for use in more complex automation applications. It offers a complete range of I/O devices comprising three components: a gateway, an electronics module and a rear panel bus.

The key element of the range is a gateway, via which all data traffic is processed on the Lenze system bus. An internal rear panel bus is used for the intra-station communication of process and parameter data, as well as diagnostic data. 

The electronics modules are isolated and manage the actual I/O functions. Up to 32 units can be combined as required to form an overall station in which each module is optimised for the individual application in which it is to be used.

Ease of application

  • Configuration
    A tailor-made system with commonsoftware for all components along with proven preconfigured software solutions will provide you with maximum reliability. The Global Drive Control V4.4 and the update to the IP 20 I/O system device file (which can be found in our Download area) offer the same type of configuration support for the Lenze I/O system as they do for Lenze controllers.
  • Programming
    Our DDS V1.4 software development environment and the update to the LenzeIOsystem.lib library (which can be found in our Download area) offer the ideal basis for easy operation of the new I/O system with our Drive PLC.

    I/O system IP20
    Modular system


Gateway

Type CAN gateway
Electrical data
Power supply 24 V DC (-15%/+20%)
CAN bus interface  
Connections 9-pos. SUB-D
Transmission rate 10 kBps to 1 MBps
Number of devices Max. 63
Permissions CE, cULus
Dimensions
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76
Order designation EPM-T110

Digital input modules

Type 8 x digital inputs 16 x digital inputs
Electrical data
Number of inputs/outputs 8/- 16/-
Rated input voltage 24 V (18...28.8 V) DC 24 V (18...28.8 V) DC
Rated load voltage - -
Signal voltage "0"/"1" 0...5 V DC/15...30 V DC 0...5 V DC/15...30 V DC
Output current per channel - -
Permissions CE, cULus CE, cULus
Dimensions    
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76 25.4 x 76 x 76
Order number EPM-T210 EPM-T221



Digital output modules

Type 8 x digital outputs 1 A 8 x digital outputs 2 A 4 x relays 16 x digital outputs 1 A
Electrical data
Number of inputs/outputs -/8 -/8 -/4 via relay -/16
Rated input voltage - - - -
Rated load voltage 24 V 18...35 V) DC 24 V 18...35 V) DC 230 V AC or 30 V DC max. 24 V (18...35 V) DC
Signal voltage "0"/"1" - - - -
Output current per channel 1 A 2 A max. summation current 10 A 230 V AC: 5 A
30 V DC: 5 A
1 A max. summation current 10 A
Permissions CE, cULus CE, cULus CE, cULus CE, cULus
Dimensions      
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76 25.4 x 76 x 76 25.4 x 76 x 76 25.4 x 76 x 76
Order number EPM-T220 EPM-T221 EPM-T222 EPM-T223


Digital I/O modules

Type 8 x digital I/O
Electrical data
Number of inputs/outputs 0...8/8...0
(total no. of channels: 8)
Rated input voltage 24 V (18...35 V) DC
Rated load voltage 24 V (18...35 V) DC
Signal voltage "0"/"1" 0...5 V/15...30 V DC
Output current per channel 1 A
Permissions CE, cULus
Dimensions  
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76
Order number EPM-T230



Analog input modules

Type 4 x analog input
Electrical data
Number of inputs/outputs 4 or 2 (4-wire)/-
Input range/output range:
Voltage +-10 V DC, +-4 V, +-400 mV, 0...50 mV
Current 0/4...20 mA, +-20 mA
Temperature PT100, PT1000, NI100, NI1000
Thermocouple J, K, N, R, S, T
Permissions CE, cULus
Dimensions
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76
Order number EPM-T310


Analog output modules

Type 4 x analog output
Electrical data
Number of inputs/outputs -/4
Input range/output range:
Voltage +-10 V, 0 to 10 V, 1 to 5 V DC
Current 0/4 to 20 mA, +-20 mA
Temperaturue -
Thermocouple -
Permissions CE, cULus
Dimensions  
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76
Order number EPM-T320


Analog input/output modules

Type 4 x analog input/output
Electrical data
Number of inputs/ outputs 2 / 2
Input area/ Output area -
Voltage 0...10 V, �10 V, 1...5 V DC
Current 0/4...20 mA, �20 mA
Temperature -
Thermoelement -
Permissions CE, cULus
Dimensions
Dimensions
(WxHxD) [mm]
25,4 x 76 x 76
Order number EPM-T330



Function modules

Type 2/4 x counter
Electrical data
Number of counters 2/4 (32/16-bit counter width)
Operating modes Incrementer/decrementer
Compare/Auto Reload functionEncoder pulses Continuous period measurement Frequency measurement
Counter frequency 1 MHz
Permissions CE, cULus
Dimensions
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76
Order number EPM-T410
Type SSI Interface
Electrical data
Number of channels 1
Inputs/outputs
Quantity 2, optionally parameterisable
Signal voltage "0" / "1" -5...7 V DC/ 13...36 V DC
Permissions CE, cULus
Dimensions
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76
Order number EPM-T411
Type 1 x counter / 16 x digital Inputs
Electrical data
Number of inputs/ outputs 16/-
Rated input voltage 24 V DC (18...28.8 V)
Signal voltage "0" / "1" 0...5 V/DC 15...30 V DC
Number of counters 1 (32-bit counter width)
Operating modes Incrementer/Decrementer
Encoder pulses
Period length measurement
Frequency measurement
Counter frequency 100 kHz
Permissions CE, cULus
Dimensions
Dimensions
(WxHxD) [mm]
25.4 x 76 x 76
Order number EPM-T430


Accessories 

Order number          
Rear panel bus, 1 module EPM-T910
Rear panel bus, 2 modules EPM-T911
Rear panel bus, 4 modules EPM-T912
Rear panel bus, 8 modules EPM-T913
Terminal strip EPM-T920
Label card EPM-T930
Label sheet EPM-T931
Terminal module EPM-T940
CAN bus connector node EPM-T950
CAN bus connector termination EPM-T951
System manual (German / English / French) EDSPM-TXXX