Interbus
Interbus
INTERBUS proves its worth primarily in commercial sized installations with many participants, for example in the automotive industry. The ring structure offers excellent diagnostic functions. Generally, INTERBUS operates efficiently at a transmission rate of 500 kbit/s. When process data are to be transmitted at higher speeds, the Lenze module is also capable of operation at 2 Mbit/s (see EMF2113IB).
Type | Communication module INTERBUS
|
Order designation | EMF2111IB |
Topology | Ring |
Max. no. of devices | Depends on the master system: with PCP => 62 participants, without PCP => 256 / number of process data words |
Max. size | Between 2 participants max. 400 m; total 13 km |
Transmission medium | Shielded twisted 5-wire cable |
Transmission rate | 500 kBit/s |
Process data size | 2-3 process data words |
Suitable for use with | 8200; 8200 vector; 9300 (all versions); except Drive PLC |
Type | Communication module INTERBUS
|
Order designation | EMF2113IB |
Topology | Ring |
Max. no. of devices | Depends on the master system; with PCP => 62 participants without PCP => 256 / number of process data words |
Max. size | Between 2 participants max. 400 m; total 13 km |
Transmission medium | Shielded twisted 5-wire cable |
Transmission rate | 500 kBit/s and 2 MBit/s |
Process data size | Max. 10 process data words (the useful process data size depends on the drive controller used) |
Suitable for use with | 8200; 8200 vector; 9300 (all versions); Drive PLC; ECS-servo system |
Special features | DIP switch for setting the process data and PCP data size; electrically isolated from the incoming bus |
Type | Function module INTERBUS
|
Function module INTERBUS |
Order designation | E82ZAFIC | E82ZAFIC001 |
Topology | Ring | Ring |
Max. no. of devices | Depends on the master system: with PCP => 62 participants; without PCP => 256 / number of process data words | Depends on the master system: with PCP => 62 participants; without PCP => 256/number of process data words |
Max. size | Between 2 participants max. 400 m; total 13 km |
Between 2 participants max. 400 m; total 13 km |
Transmission medium | Shielded twisted pair 3x2-wire cable | Shielded twisted pair 3x2-wire cable |
Transmission rate | 500 kBit/s | 500 kBit/s |
Process data size | 1 word - 6 words | 1 word - 6 words |
Suitable for use with | 8200 vector | 8200 vector |
Special features | Terminal for activating the controller inhibit and the external power supply to the module | As the E82ZAFIC but with plug-in terminals |
Type | Function module INTERBUS PT |
Order designation | E82ZAFIC010 |
Topology | Ring |
Max. no. of devices | Depends on the master system: with PCP => 62 participants; without PCP => 256 / number of process data words |
Max. size | Between 2 participants max. 400 m; total 13 km |
Transmission medium | Shielded twisted pair 3x2-wire cable |
Transmission rate | 500 kBit/s |
Process data size | 1 word - 6 words |
Suitable for use with | 8200 vector |
Special features | As the E82ZAFIC but with plug-in terminals |